Description
Control Valve 85 TA Canature for Softener
The 85TA Canature control valve is an electronic alternating twin valve designed to handle high flows of hard water. By allowing more than one tank simultaneously, the system provides a continuous supply of softened water by allowing regeneration in one tank and softening in another.
It can be configured to have regeneration defined by time clock, immediate regeneration or delayed regeneration in periods of low demand for softened water.
The 85TA Canature control valve is NSF/ANSI 44 certified and is warranted against manufacturing defects for 5 years.
Water flow at 50 psi at the inlet
Continuous flow (15 psi pressure drop)
Maximum flow (25 psi pressure drop)
Maximum Backwash (25 psi pressure drop)
Volumetric flow coefficient
Common applications
Softener
Electrical specifications
Input voltage
Output voltage
Operating parameters
Operating pressure
Maximum temperature
1.
NSF certified quality
The 85TA control valve is NSF/ANSI 44 certified.
2.
Automatic rinsing
Automatically performs rinsing during periods of non-use or inactivity.
3.
Flow meter included
It monitors and controls the flow entering the treatment system to make the processes more efficient.
4.
Alternating tank system
Uninterrupted supply of softened water thanks to alternating tanks.
5.
Integrated manifold
The manifold allows for easy installation and flow distribution within the alternate tank system.
6.
Programmable regeneration
Intuitive and adjustable regeneration cycles according to treatment needs.
7.
Optimized brine
Optimal brine accuracy based on mean saturation.
8.
Higher dilution of salt in pellets
The brine tank is filled with softened water, which improves salt dilution.
9.
5-year warranty.
Product guaranteed for 5 years in case of manufacturing defects.
Comparative table of control valves
Features |
65CC |
765 |
565 |
785 |
89 |
95 |
105 |
Valve material |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Input / Output |
3/4″, 1″ |
3/4″, 1″ |
3/4″, 1″ |
3/4″, 1″ |
1″ |
1″, 1-1/4″, 1 1/2″ |
2″ |
Service flow (gpm) |
20 GPM |
20 GPM |
20 GPM |
20 GPM |
27 GPM |
39 GPM |
70 GPM |
Maximum flow (gpm) |
26 GPM |
26 GPM |
26 GPM |
26 GPM |
35 GPM |
50 GPM |
90 GPM |
Backwash flow (gpm) |
7 GPM |
7 GPM |
7 GPM |
17 GPM |
27 GPM |
32 GPM |
70 GPM |
Upflow / Downflow |
NA / X |
NA / X |
NA / X |
X / X |
X / X |
NA / X |
NA / X |
Adjustable cycle time |
NA |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Duplex |
NA |
NA |
NA |
NA |
NA |
Yes |
Yes |
Multiplex |
NA |
NA |
NA |
NA |
NA |
Yes |
Yes |
Drainage size |
1/2″ |
1/2″ |
1/2″ |
1/2″ |
3/4″ |
3/4″, 1″ |
1.5″ o 2″ |
Brine size |
3/8″ |
3/8″ |
3/8″ |
3/8″ |
3/8″ |
3/8″, 1/2″ |
1/2″ |
Pilot distributor |
1.05″ |
1.05″ |
1.05″ |
1.05″ |
1.05″ |
1.5″ |
1.5″ |
Filter tank size |
10″ |
10″ |
10″ |
16″ |
18″ |
21″ |
30″ |
Softener tank size |
16″ |
16″ |
16″ |
16″ |
18″ |
24″ |
36″ |