Description
89 Canature control valve for filter or softener
The 89 Canature control valve is NSF/ANSI 44 certified, ensuring superior quality in design and construction. In conjunction with its 4-line LCD touch panel, it allows a quick and intuitive display of the data, facilitating the user’s operation.
It incorporates an automatic cleaning system that prevents the formation of bacteria during periods of inactivity. In addition, its adjustable backwash feature can save up to 2,000 gallons of water per year. It should also be noted that the brine is adjusted with high precision according to the saturation of the medium, guaranteeing maximum efficiency.
The valve is warranted for 7 years against manufacturing defects.
Water flow at 50 psi at the inlet
Continuous flow (15 psi pressure drop)
Maximum flow (25 psi pressure drop)
Maximum Backwash (25 psi pressure drop)
Volumetric flow coefficient
Standard applications
Softener
Filter
Electrical specifications
Input voltage
Output voltage
Safety certificate
Operating parameters
Maximum operating pressure
Working temperature limit
1.
NSF/ANSI 44
Quality in design, backed by NSF/ANSI 44 certification
2.
LCD panel
View data quickly and intuitively on its 4-line touch screen.
3.
High efficiency
Optimum performance thanks to upflow precision.
4.
Rapid regeneration
Rapid regeneration of protection against capacity limit demand.
5.
Automatic cleaning
Automatic rinsing system during periods of non-use, which prevents the formation of bacteria.
6.
Adjustable backwash
Backwash customization capable of saving up to 2,000 gallons per year.
7.
Efficient salt dilution
8.
Data preservation
Self-charging capacitor that maintains date and time for 48 hours, with permanent memory for programming.
9.
Integrated design
It includes a built-in turbine flow meter, a bypass system and all necessary accessories for easy installation.
10.
Measuring modes
Includes immediate meter, delayed meter, meter override, and clock modes for vacation and calendar settings.
11.
Brine according to saturation
High brine precision adjusted according to the saturation of the medium.
12.
7-year warranty
Equipment insured for a period of seven years against manufacturing failures.
Comparative table of control valves
Features |
65CC |
765 |
565 |
785 |
89 |
95 |
105 |
Valve material |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Input / Output |
3/4″, 1″ |
3/4″, 1″ |
3/4″, 1″ |
3/4″, 1″ |
1″ |
1″, 1-1/4″, 1 1/2″ |
2″ |
Service flow (gpm) |
20 GPM |
20 GPM |
20 GPM |
20 GPM |
27 GPM |
39 GPM |
70 GPM |
Maximum flow (gpm) |
26 GPM |
26 GPM |
26 GPM |
26 GPM |
35 GPM |
50 GPM |
90 GPM |
Backwash flow (gpm) |
7 GPM |
7 GPM |
7 GPM |
17 GPM |
27 GPM |
32 GPM |
70 GPM |
Upflow / Downflow |
NA / X |
NA / X |
NA / X |
X / X |
X / X |
NA / X |
NA / X |
Adjustable cycle time |
NA |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Duplex |
NA |
NA |
NA |
NA |
NA |
Yes |
Yes |
Multiplex |
NA |
NA |
NA |
NA |
NA |
Yes |
Yes |
Drainage size |
1/2″ |
1/2″ |
1/2″ |
1/2″ |
3/4″ |
3/4″, 1″ |
1.5″ o 2″ |
Brine size |
3/8″ |
3/8″ |
3/8″ |
3/8″ |
3/8″ |
3/8″, 1/2″ |
1/2″ |
Pilot distributor |
1.05″ |
1.05″ |
1.05″ |
1.05″ |
1.05″ |
1.5″ |
1.5″ |
Filter tank size |
10″ |
10″ |
10″ |
16″ |
18″ |
21″ |
30″ |
Softener tank size |
16″ |
16″ |
16″ |
16″ |
18″ |
24″ |
36″ |