Description
Canature 95MTS control valve for filter or softener
The Canature 95MTS control valve is capable of high flow rates, whether for commercial or residential applications, thanks to its quality construction with reliable piston, seals and electronic sensors.
Its large display makes the operation, programming and monitoring of the valve user-friendly, as it shows information such as time, remaining capacity, as well as flow rate.
The valve is warranted for 5 years against manufacturing defects.
Water flow at 50 psi at the inlet
Continuous flow (15 psi pressure drop)
Maximum flow (25 psi pressure drop)
Maximum Backwash (25 psi pressure drop)
Volumetric flow coefficient
Standard applications
Softener
Filter
Electrical specifications
Input voltage
Output voltage
Safety certificate
Operating parameters
Maximum operating pressure
Working temperature limit
1.
High capacity
Ideal for filtration or softening systems in both residential and commercial environments.
2.
Quick and easy assembly
It includes fast connections, advanced electronic sensors and waterproof electrical system.
3.
Integrated turbine meter
The equipment integrates a turbine meter for accurate measurement of water flow.
4.
Energy backup
Capable of maintaining the time settings for 48 hours without power, keeping the general settings in its permanent memory.
5.
Intuitive interface
It includes a display that facilitates the visualization of the current time, available capacity and water flow.
6.
Cycle programming
Adjustment and customization of regeneration cycles based on system needs.
7.
Multiple tanks
Allows interconnection of up to 8 tanks in the system to obtain softened water at all times.
8.
Dynamic tank management
In multi-tank systems, they operate on a flow demand basis.
9.
5-year warranty
Five-year warranty for defects originated in the manufacturing process.
Comparative table of control valves
Features |
65CC |
765 |
565 |
785 |
89 |
95 |
105 |
Valve material |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Noryl (PPO) |
Input / Output |
3/4″, 1″ |
3/4″, 1″ |
3/4″, 1″ |
3/4″, 1″ |
1″ |
1″, 1-1/4″, 1 1/2″ |
2″ |
Service flow (gpm) |
20 GPM |
20 GPM |
20 GPM |
20 GPM |
27 GPM |
39 GPM |
70 GPM |
Maximum flow (gpm) |
26 GPM |
26 GPM |
26 GPM |
26 GPM |
35 GPM |
50 GPM |
90 GPM |
Backwash flow (gpm) |
7 GPM |
7 GPM |
7 GPM |
17 GPM |
27 GPM |
32 GPM |
70 GPM |
Upflow / Downflow |
NA / X |
NA / X |
NA / X |
X / X |
X / X |
NA / X |
NA / X |
Adjustable cycle time |
NA |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Duplex |
NA |
NA |
NA |
NA |
NA |
Yes |
Yes |
Multiplex |
NA |
NA |
NA |
NA |
NA |
Yes |
Yes |
Drainage size |
1/2″ |
1/2″ |
1/2″ |
1/2″ |
3/4″ |
3/4″, 1″ |
1.5″ o 2″ |
Brine size |
3/8″ |
3/8″ |
3/8″ |
3/8″ |
3/8″ |
3/8″, 1/2″ |
1/2″ |
Pilot distributor |
1.05″ |
1.05″ |
1.05″ |
1.05″ |
1.05″ |
1.5″ |
1.5″ |
Filter tank size |
10″ |
10″ |
10″ |
16″ |
18″ |
21″ |
30″ |
Softener tank size |
16″ |
16″ |
16″ |
16″ |
18″ |
24″ |
36″ |
More information about softeners: