Canature Hydrotech 105 Control Valve

$1.00

  • Valve body material: Noryl (PPO)
  • Inlet / Outlet: 1.5″ or 2″ NPT
  • Base: 4.0″ – 8UN
  • Pilot distributor: 1.5″ (pipe)
  • Drain Line: 1.5″ or 2″ NPT
  • Brine line: 1/2″ NPT
  • Shipping weight: 15 kg

Description

Control valve 105 Canature control valve for filter or softener

The 105 Canature electronic control valve with 2″ inlet and outlet connections and 4″ tank thread with NSF 44 certification was designed for high service and backwash flow rates.

Among its features, it integrates a precision flow meter, which allows monitoring of water consumption. Its intuitive interface facilitates the programming of regeneration cycles, which can be fine-tuned to suit the specific needs of each system. This level of customization extends to the multi-tank system, as it is capable of interconnecting up to 8 units, which are automatically activated or deactivated according to flow demand. It is also available with or without raw water piston.

It has a 5-year warranty against manufacturing defects.

Flows:

Continuous flow (15 psi pressure drop)
70 GPM
Maximum flow (25 psi pressure drop)
90 GPM
Maximum Backwash (25 psi pressure drop)
70 GPM
Volumetric flow coefficient
18 Cv

Standard applications

Filter
Diameter up to 36 inches
Softener
Diameter up to 30 inches

Electrical specifications

Input voltage
110V at 60Hz
Output voltage
24V AC at 50/60Hz (others available)

Operating parameters

Operating pressure
Range 20 to 125 psi
Working temperature limit
From 1°C to 43°C

1.

NSF/ANSI 44

Maintains safety, performance and quality standards established by NSF.

2.

Integrated flow meter

Controls the amount of water passing through the system.

3.

Programmable regeneration

Simple configuration of regeneration periods.

4.

Up to 8 tanks connected

Designed for large interconnected multi-tank systems

5.

Dynamic response to flow

The tanks are activated or deactivated based on the required water flow.

6.

Auxiliary outlets

Ability to add up to two additional relays or programmable outputs.

7.

Operates after power outages

Capable of continuing to monitor and record water flow for up to nine hours after a power outage.

8.

Efficient regeneration

Softened water is used in the regeneration process to improve the quality of the treatment.

9.

5-year warranty

It includes a five-year warranty to cover any manufacturing defects.

Comparative table of control valves

Control Valve 765 Canature
Control Valve 565 Canature
89 Canature control valve
Control Valve 95MTS Canature
Control Valve 105 Canature
Features
65CC
765
565
785
89
95
105
Valve material
Noryl (PPO)
Noryl (PPO)
Noryl (PPO)
Noryl (PPO)
Noryl (PPO)
Noryl (PPO)
Noryl (PPO)
Input / Output
3/4″, 1″
3/4″, 1″
3/4″, 1″
3/4″, 1″
1″
1″, 1-1/4″, 1 1/2″
2″
Service flow (gpm)
20 GPM
20 GPM
20 GPM
20 GPM
27 GPM
39 GPM
70 GPM
Maximum flow (gpm)
26 GPM
26 GPM
26 GPM
26 GPM
35 GPM
50 GPM
90 GPM
Backwash flow (gpm)
7 GPM
7 GPM
7 GPM
17 GPM
27 GPM
32 GPM
70 GPM
Upflow / Downflow
NA / X
NA / X
NA / X
X / X
X / X
NA / X
NA / X
Adjustable cycle time
NA
Yes
Yes
Yes
Yes
Yes
Yes
Duplex
NA
NA
NA
NA
NA
Yes
Yes
Multiplex
NA
NA
NA
NA
NA
Yes
Yes
Drainage size
1/2″
1/2″
1/2″
1/2″
3/4″
3/4″, 1″
1.5″ o 2″
Brine size
3/8″
3/8″
3/8″
3/8″
3/8″
3/8″, 1/2″
1/2″
Pilot distributor
1.05″
1.05″
1.05″
1.05″
1.05″
1.5″
1.5″
Filter tank size
10″
10″
10″
16″
18″
21″
30″
Softener tank size
16″
16″
16″
16″
18″
24″
36″