Hydrofit Pipe

Hose for water filters in 1/4, 3/8 and 1/2 inch,

Meets NSF under NSF / ANSI Standard 61. Components for drinking water for human use.

Product images are illustrative and may vary from the physical product.

HYDROFIT NSF HOSE

PT04 - 1/4 ”HOSE (500 FEET ROLL)

Code Description
PT04-BK-0500 1/4 ”Polyethylene Hose - Black
PT04-BL-0500 1/4 ”Polyethylene Hose - Blue
PT04-GN-0500 1/4 ”Polyethylene Hose - Green
PT04-NA-0500 1/4 ”Polyethylene Hose - Natural
PT04-OG-0500 1/4 ”Polyethylene Hose - Orange
PT04-RD-0500 1/4 ”Polyethylene Hose - Red
PT04-WH-0500 1/4 ”Polyethylene Hose - White
PT04-YL-0500 1/4 ”Polyethylene Hose - Yellow

PT06 - 3/8 ”HOSE (500 FEET ROLL)

Code Description
PT06-BK-0500 3/8 ”Polyethylene Hose - Black
PT06-BL-0500 3/8 ”Polyethylene Hose - Blue
PT06-NA-0500 3/8 ”Polyethylene Hose - Natural
PT06-RD-0500 3/8 ”Polyethylene Hose - Red
PT06-WH-0500 3/8 ”Polyethylene Hose - White

PT08 - 1/2 ”HOSE (250 FEET ROLL)

Provider Number Description
PT08-BK-0250 1/2 ”Polyethylene Hose - Black
PT08-BL-0250 1/2 ”Polyethylene Hose - Blue
PT08-NA-0250 1/2 ”Polyethylene Hose - Natural
PT08-WH-0250 1/2 ”Polyethylene Hose - White

HDF-TC - HOSE CUTTER

Provider Number Description
HDF-TC Tube Cutter

Operating Pressure & Temperature Range:

  • 1/4 ”& 3/8” 230 PSI at 70 ° F (15 BAR at 20 ° C)
    Maximum: 120 PSI at 150 ° F (8 BAR at 65 ° C)
  • 1/2 ”150 PSI at 70 ° F (10 BAR at 20 ° C)
    Maximum: 90 PSI at 150 ° F (6 BAR at 65 ° C)

Static Pressure - 3 times maximum pressure or 300 psi minimum
Burst Pressure - 4 times maximum pressure or 400 psi minimum
Cyclic Pressure - 100,000 cycles at 150 psi

HOSE DIAMETER
External diameter Internal diameter
1/4 ″ 0.160 ″
3/8 ″ 0.250 ″
1/2 ″ 0.37 ″


Instructions
 of installation:

STEP 1. CUT THE HOSE
Cut the Hose squarely. Make sure the Hose has a smooth outside diameter without burrs, chamfers or notice marks before inserting it into the fitting. Hose that has not been properly cut off can cause drips and leaks.

STEP 2. INSERT THE HOSE
Push the Hose through the crown and O-Ring until it bottoms out against the quick connector stop. The crown holds the tube in place and the O-ring provides a leak resistant seal. If you need to remove the tube always re-cut before connecting again. Burrs on the tube can cause leakage.

STEP 3. INSPECT AND TEST
Push and pull the Quick Connect Hose in and out to make sure it has been installed correctly. Test and inspect the installation for leaks.

REMOVE THE HOSE
To remove the hose, push the crown of the quick connect against the body while pulling the Hose out of the fitting to release it. * Press the QUICK CONNECT in the opposite direction.